Skip to main content
Siemens 3VA2063-7KP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-7KP32-0AA0 SENTRON MCCB, 63 A, 3-Pole, ETU85

MPN3VA2063-7KP32-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2063-7KP32-0AA0, 63 A, 3-pole, ETU850 electronic trip unit, line protection design, 330 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-7KP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2063-7KP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3 kA
Power loss, max.3 W
3VA2063-7KP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2063-7KP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-7KP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-7KP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-7KP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2063-7KP32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current, built around the ETU850 electronic trip unit.

This MCCB delivers 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3 kA at 690 V. That 330 kA at 240 V is the headline number — it means this breaker can interrupt a fault current up to 330,000 amps at that voltage without welding or rupturing. For a 63 A frame, that's enormous headroom, which makes it useful downstream of large transformers or in high-fault-capacity industrial services where you need to maintain selectivity with upstream gear. The 690 V rating drops to 3 kA, so if you're on a 690 V system, you're limited to relatively low available fault current.

Dimensions: 105 mm wide, 181 mm tall, 86 mm deep.

Temperature derating and ratings

The 63 A continuous rating holds flat from 40 °C through 70 °C ambient (–) — no derating needed in a warm panel, which is a practical advantage. Rated insulation voltage is 800 V, so it's suitable for 480 V and 600 V class systems with margin. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Power loss is 3 W maximum, negligible for panel heat calculations.

Frequently asked questions

What is 3VA2063-7KP32-0AA0's listed depth?

The depth is 86 mm.

What is 3VA2063-7KP32-0AA0's listed width?

The width is 105 mm.

MPN
3VA2063-7KP32-0AA0