Skip to main content
Siemens 3VA2063-8KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-8KQ42-0AA0 SENTRON MCCB, 63 A, 4-Pole, ETU86

MPN3VA2063-8KQ42-0AA0
Active

Siemens SENTRON 3VA2063-8KQ42-0AA0, molded case circuit breaker, 4-pole, 63 A rated current Iu, ETU860 overcurrent release, line protection, 440 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-8KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2063-8KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.3 W
3VA2063-8KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2063-8KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-8KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-8KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-8KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2063-8KQ42-0AA0 — 63 A MCCB with ETU860 Release

The Siemens SENTRON 3VA2063-8KQ42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated at 63 A continuous current Iu, with no derating across the full 40 °C to 70 °C operating range — the same 63 A holds at every temperature step, so you don't lose headroom in a warm enclosure. It carries the ETU860 electronic overcurrent release, configurable for line protection duty. The 440 kA interrupting rating at 240 V (330 kA at 415 V / 440 V, 220 kA at 500 V, 52.5 kA at 690 V) means it clears high-fault currents upstream of a distribution panel without cascading to the main breaker — sized for high-capacity transformer secondaries or busway feeds.

Dimensions are 140 mm wide by 181 mm high by 86 mm deep — the 4-pole width is the key fit check for existing MCCB buckets or DIN-rail adapters. IP40 on the front face protects against tool drops during commissioning; the rear and sides are unrated, so clearance to grounded metal per the manufacturer's mounting rules applies. The 86 mm depth (3.39 in) leaves room behind the panel door for wiring gutters or busbar stacks.

Communication and Accessory Provisions

This variant includes a communication function (fieldbus or Modbus interface via the ETU860), enabling power monitoring and remote trip indication. An optional motor drive extension is available for remote charging and closing. No undervoltage release or voltage trigger is fitted on this order code — those are separate add-on modules. The ground-fault monitoring version uses summation current formation on L + N conductors, so it detects leakage without a separate sensor core. Maximum power loss is 3 W — negligible for panel thermal budgeting.

Frequently asked questions

What is the interrupting rating of 3VA2063-8KQ42-0AA0 at 415 V?

330 kA at 415 V, and the same 330 kA at 440 V.

Does the 63 A rating derate at high ambient temperatures?

No derating — the 63 A rating holds from 40 °C through 70 °C ambient. The same current is available at every temperature step in that range.

Will 3VA2063-8KQ42-0AA0 drop into a panel specified around 3VA2063-8JQ42-0AA0?

Yes, the mechanical footprint (140 mm width, 181 mm height, 86 mm depth) and 4-pole format are identical between the two. The difference is the overcurrent release: the -8KQ42 carries the ETU860 (electronic, with communication), while the -8JQ42 uses a simpler ETU. Panel cutouts and busbar connections are the same.

How do I get current pricing and availability for 3VA2063-8KQ42-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

MPN
3VA2063-8KQ42-0AA0