Skip to main content
Siemens 3VA2063-8KQ46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2063-8KQ46-0AA0 SENTRON MCCB, 63 A, 4-Pole, 800 V

MPN3VA2063-8KQ46-0AA0
Active

Siemens SENTRON 3VA2063-8KQ46-0AA0, molded case circuit breaker, 4-pole, 63 A continuous, 800 V insulation, line protection design, communication capable.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2063-8KQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2063-8KQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.3 W
3VA2063-8KQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2063-8KQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2063-8KQ46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2063-8KQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2063-8KQ46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2063-8KQ46-0AA0 is a 4-pole molded case circuit breaker rated for 63 A continuous current at 40 °C through 70 °C — no derating needed across that band, which simplifies panel schedules in warm enclosures. Insulation voltage is rated 800 V, and the interrupting capacity hits 440 kA at 240 V, 330 kA at 415/440 V, 220 kA at 500 V, and 52.5 kA at 690 V. That spread covers most industrial distribution voltages without a second breaker tier. It is designed for line protection — the primary role is feeder or main breaker in a panel, not motor-circuit protection (no integrated overload). Ground-fault monitoring uses summation current formation on L+N, and the unit includes a communication function for integration into a higher-level monitoring system.

Four poles in that width is typical for a 63 A frame; verify busbar or lug kit compatibility if replacing an older 3VA1 or 3WL breaker.

Frequently asked questions

What is the closest functional second-source for 3VA2063-8KQ46-0AA0?

The closest peer is 3VA2063-8JQ42-0AA0 — same 63 A, 4-pole SENTRON frame. The 8JQ42 lacks the communication function and ground-fault monitoring (summation current) that the 8KQ46 includes. If those features are not required, the 8JQ42 is a direct mechanical fit; if they are, the 8KQ46 is the only correct variant.

How do I get current pricing and availability for 3VA2063-8KQ46-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to confirm current pricing and availability — no stock or lead-time figures are published here.

Will 3VA2063-8KQ46-0AA0 drop into a panel specified around 3VA2063-8JQ42-0AA0 without rewiring?

Yes — both share the same SENTRON 3VA2 frame dimensions (181 x 140 x 86 mm) and 4-pole busbar pitch. The wiring footprint is identical; the only difference is the communication and ground-fault monitoring circuitry on the 8KQ46. No rewiring needed for the power path.

MPN
3VA2063-8KQ46-0AA0