Siemens 3VA2110-0KP46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-0KP46-0AA0 SENTRON MCCB, 100 A, ETU850, 440

MPN3VA2110-0KP46-0AA0
Active

Siemens SENTRON 3VA2110-0KP46-0AA0, molded case circuit breaker, 4-pole, 100 A continuous, ETU850 electronic trip unit, 440 kA breaking capacity at 415 V AC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-0KP46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-0KP46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.7.7 W
3VA2110-0KP46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-0KP46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-0KP46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-0KP46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-0KP46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-0KP46-0AA0 is a 4-pole molded case circuit breaker rated 100 A continuous at 40 °C, with an ETU850 electronic trip unit that supports adjustable N-conductor protection (OFF, 20 % to 160 %).

At 86 mm deep, 140 mm wide, and 181 mm tall, the 3VA2110-0KP46-0AA0 fits the standard SENTRON 3VA frame footprint.

Trip unit and protection capabilities

The N-conductor protection can be set from OFF to 20 %–160 % of the rated current, which is useful for systems with harmonic loads or unbalanced neutral currents. Rated insulation voltage is 800 V, and the breaker handles ambient temperatures from -25 °C to 70 °C, with no derating needed up to 70 °C (100 A continuous across the full range).

Frequently asked questions

How do I get current pricing and availability for 3VA2110-0KP46-0AA0?

Submit an RFQ through this listing. We source through multiple independent distribution channels and confirm current pricing and availability at quote time.

What is 3VA2110-0KP46-0AA0's listed depth and width?

The depth is 86 mm and the width is 140 mm (4-pole).

Will 3VA2110-0KP46-0AA0 drop into a panel specified around 3VA2116-5JP32-0AE0 without rewiring?

Both breakers share the same SENTRON 3VA frame and 4-pole width, so the physical footprint and DIN-rail mounting are identical. However, the 3VA2116-5JP32-0AE0 has a different trip unit and current rating — verify the lug kit, busbar connections, and protection settings before swapping.

What compliance documentation does Siemens provide for 3VA2110-0KP46-0AA0?

Siemens typically provides RoHS and REACH declarations, plus UL and IEC certification documentation for the SENTRON 3VA series. Specific certificates can be requested at quote time.