Skip to main content
Siemens 3VA2110-0MN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-0MN32-0AA0 SENTRON MCCB, 100 A, 440 kA at 41

MPN3VA2110-0MN32-0AA0
Active

Siemens SENTRON 3VA2110-0MN32-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU350M electronic trip unit, 440 kA at 415 V, motor protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2110-0MN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-0MN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.7.7 W
3VA2110-0MN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-0MN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-0MN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-0MN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-0MN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Panel fit and thermal reality

The 3VA2110-0MN32-0AA0 measures 105 mm wide by 181 mm tall by 86 mm deep — a standard 3-pole MCCB footprint that drops into a SENTRON distribution board or a DIN-rail adapter plate. Power loss maxes at 7.7 W, which is modest enough that you don't need forced ventilation in a typical 200 A panel, but if you're packing six of these side-by-side in a 40 °C ambient, do the thermal calc.

Where the 3VA2110 sits vs. the 3VA1110 series

If your panel was originally built around a 3VA1110-5ED32-0AA0, the 3VA2110-0MN32-0AA0 is a larger-frame MCCB with higher interrupting capacity — 440 kA vs. the 1110's typical 65 kA at 415 V. The 3VA2110 is physically taller (181 mm vs. roughly 130 mm for the 1110), so it won't drop into the same mounting footprint without a backplate or busbar adapter.

Frequently asked questions

Where can I buy 3VA2110-0MN32-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA2110-0MN32-0AA0 drop into a panel built around 3VA1110-5ED32-0AA0?

Not without mechanical adaptation. The 3VA2110 is taller (181 mm vs. roughly 130 mm) and has a different mounting footprint. The 100 A rating and ETU350M trip are electrically similar, but the 2110 delivers 440 kA interrupting capacity versus the 1110's typical 65 kA — useful if your available fault current exceeds 65 kA.

What is the depth of 3VA2110-0MN32-0AA0?

86 mm (3.39 in).

What is the width of 3VA2110-0MN32-0AA0?

105 mm (4.13 in).

MPN
3VA2110-0MN32-0AA0