Skip to main content
Siemens 3VA2110-5HK42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HK42-0AA0 SENTRON MCCB, 100 A, 4-Pole, ETU3

MPN3VA2110-5HK42-0AA0
Active

Siemens SENTRON 3VA2110-5HK42-0AA0, molded case circuit breaker, 4-pole, 100 A, ETU340 electronic trip unit, line protection design, breaking capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HK42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-5HK42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5HK42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5HK42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HK42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-5HK42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HK42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this MCCB delivers — 100 A, 4-pole, ETU340

The Siemens SENTRON 3VA2110-5HK42-0AA0 is a 4-pole molded case circuit breaker rated for 100 A continuous current across the full ambient range from -25 °C to 70 °C, with no derating needed up to 70 °C. Breaking capacity hits 187 kA at 240 V and stays at 121 kA through 440 V, then drops to 75.6 kA at 500 V and 3.7 kA at 690 V. That 187 kA figure at 240 V is the headline number for high-fault panelboards; at 415/440 V the 121 kA still covers most industrial service-entrance applications. Power loss is 10 W maximum, which matters for thermal management in a dense MCC lineup.

Sourcing and lifecycle — active production, quoted to order

The 3VA series is Siemens' current-generation MCCB platform, so replacements and spare parts are straightforward. No need to stockpile or hunt for NOS.

That 140 mm width for a 4-pole frame is standard for the 3VA2 frame size — it occupies the same panel footprint as other 3VA2 breakers.

How the ETU340 trip unit works for coordination

That short-time delay lets you coordinate downstream breakers for selective tripping, so a fault on a branch doesn't take out the main. This is the key difference from a thermal-magnetic MCCB: you get adjustable pickup and time bands, not fixed curves.

Frequently asked questions

Where can I buy 3VA2110-5HK42-0AA0 and how do I get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ and we'll confirm availability and current pricing at quote time.

What is 3VA2110-5HK42-0AA0's breaking capacity at 240 V?

The breaking capacity at 240 V is 187 kA. At 415 V and 440 V it's 121 kA, at 500 V it's 75.6 kA, and at 690 V it's 3.7 kA.

What compliance documentation does Siemens provide for 3VA2110-5HK42-0AA0?

As a current-production SENTRON MCCB, standard documentation includes IEC/EN 60947-2 compliance, CE marking, and manufacturer declarations for RoHS and REACH. UL/CSA listings vary by variant; verify the specific order code suffix for UL File number.

MPN
3VA2110-5HK42-0AA0