Skip to main content
Siemens 3VA2110-5HK46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HK46-0AA0 SENTRON MCCB, 100 A, 4-Pole, ETU3

MPN3VA2110-5HK46-0AA0
Active

Siemens SENTRON 3VA2110-5HK46-0AA0, molded case circuit breaker, 4-pole, 100 A, ETU340 electronic trip unit, line protection, 187 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2110-5HK46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2110-5HK46-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V76 kA
Breaking capacity at 690 V17 kA
Power loss, max.10 W
3VA2110-5HK46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
3VA2110-5HK46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HK46-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-5HK46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HK46-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

The Siemens SENTRON 3VA2110-5HK46-0AA0 is a 4-pole molded case circuit breaker rated for 100 A continuous current with no derating across the full ambient range from 40 °C to 70 °C — that means the full 100 A is available even in a hot panel, a real advantage when the enclosure sits next to a furnace line or in a crowded switchroom. Its interrupting capacity reaches 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, then 76 kA at 500 V, and 17 kA at 690 V. These are the numbers that govern selectivity coordination with upstream and downstream devices — if your fault-current study shows 150 kA available at the panelboard on a 480 V system, this breaker holds the line without cascading. The electronic trip unit is an ETU340, which provides adjustable long-time, short-time, and instantaneous protection along with adjustable N-conductor protection (OFF, 50%, 100%).

The IP40 front protection means it is suited for installation inside a panel with a door; not for washdown environments. Mechanical endurance is rated at 20,000 operations, sufficient for distribution applications where the breaker is operated infrequently.

MPN
3VA2110-5HK46-0AA0