Skip to main content
Siemens 3VA2110-5HL32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HL32-0AH0 MCCB, 100 A, 3-Pole, ETU320, 187

MPN3VA2110-5HL32-0AH0

Siemens SENTRON 3VA2110-5HL32-0AH0, molded case circuit breaker, 3-pole, 100 A, ETU320 electronic trip unit, line protection, breaking capacity 187 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2110-5HL32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2110-5HL32-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.10 W
3VA2110-5HL32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2110-5HL32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HL32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-5HL32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HL32-0AH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2110-5HL32-0AH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current (Iu) with an ETU320 electronic trip unit, configured for line protection. Its interrupting capacity hits 187 kA at 240 V and 121 kA at 415 V, which means it can clear high-fault currents without cascading upstream — a key spec for main or feeder breakers in industrial switchboards where SCCR headroom matters. The ETU320 trip unit provides adjustable thermal-magnetic or electronic protection curves (L, S, I, G depending on configuration), though this variant ships without ground-fault monitoring or communication functions. The 100 A rating holds flat from 40 °C to 50 °C, then derates linearly to 85 A at 70 °C — useful to know when the breaker sits in a warm enclosure near other heat sources.

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits most Siemens SENTRON mounting bases and busbar systems.

Frequently asked questions

How do I get current pricing and availability for 3VA2110-5HL32-0AH0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 3VA2110-5HL32-0AH0 drop into a panel specified around 3VA1110-5EE32-0JA0 without rewiring?

The 3VA2110-5HL32-0AH0 shares the same 3-pole form factor and SENTRON mounting footprint as the 3VA1110 series, so it fits the same busbar and enclosure cutout. The key difference is the ETU320 electronic trip unit versus the thermal-magnetic release on the 3VA1110 — verify the protection curve and auxiliary contact wiring before swapping.

What compliance documentation does this brand provide for 3VA2110-5HL32-0AH0?

Siemens SENTRON MCCBs are typically supplied with IEC 60947-2 certification, CE marking, and UKCA; RoHS and REACH declarations are available from the manufacturer. Specific document pack should be requested at order time.

MPN
3VA2110-5HL32-0AH0