Siemens 3VA2110-5HL32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HL32-0JC0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5HL32-0JC0

Siemens SENTRON 3VA2110-5HL32-0JC0, Molded case circuit breaker, 3-pole, 100 A, line protection, with shunt trip (STL) and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HL32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-5HL32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5HL32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5HL32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HL32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-5HL32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HL32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

100 A MCCB with flat thermal derating and high SCCR

The Siemens SENTRON 3VA2110-5HL32-0JC0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, with a flat derating curve from 40 °C through 70 °C — no reduction needed across that full ambient span, which simplifies panel thermal budgeting in warm enclosures. Breaking capacity sits at 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 240 V figure covers most North American distribution panels, while the 415/440 V numbers handle European 400 V grids with headroom for high-fault locations like substation secondaries.

Dimensions are 86 mm deep, 105 mm wide, and 181 mm high (3.39 x 4.13 x 7.13 in) — the 105 mm width is standard for a 3-pole SENTRON 3VA2 frame, so it drops into existing panel layouts without re-spacing the DIN rail or busbar system. Maximum power loss is 10 W, which keeps internal cabinet heating low even under full load — relevant for sealed enclosures with limited convection.

Frequently asked questions

What is 3VA2110-5HL32-0JC0's listed depth?

The depth is 86 mm (3.39 in).

What is 3VA2110-5HL32-0JC0's listed width?

The width is 105 mm (4.13 in).

MPN
3VA2110-5HL32-0JC0