Skip to main content
Siemens 3VA2110-5HL32-0KL0 — Molded Case Circuit Breakers (MCCB)

3VA2110-5HL32-0KL0 SENTRON MCCB, 100A 3-Pole, 187kA@240V

MPN3VA2110-5HL32-0KL0

Siemens SENTRON 3VA2110-5HL32-0KL0, molded case circuit breaker, 3-pole, 100 A continuous, adjustable overload 150–1200 A, interrupting capacity 187 kA at 240 V, line protection design with shunt trip release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5HL32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2110-5HL32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-5HL32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5HL32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5HL32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2110-5HL32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5HL32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-5HL32-0KL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, with an adjustable overload trip range from 150 A to 1200 A. It's designed for line protection in distribution panels and motor control centers.

Interrupting capacity and thermal performance

This MCCB delivers an interrupting capacity of 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — covering most industrial service voltages without needing a current-limiting upstream breaker. The thermal rating holds steady at 100 A across the full ambient range from 40 °C to 70 °C, so no derating curve to worry about in a warm panel.

Physical fit and mounting

At 86 mm deep, 105 mm wide, and 181 mm tall, it fits a standard MCCB cutout in a distribution panel or motor control center. The 105 mm width is typical for a 3-pole frame in this class — check your bus-bar spacing if replacing an older narrow-frame breaker.

Auxiliary and release options

Factory-fitted with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ type), plus a shunt trip (STL) release for remote tripping. No undervoltage release or ground-fault monitoring on this variant — those are separate order codes if your spec requires them.

Environmental limits and power loss

Operates from -25 °C to 70 °C, stores from -40 °C to 80 °C. Max power dissipation is 10 W — negligible for panel thermal calculations but worth noting if you're packing multiple breakers in a sealed enclosure.

Frequently asked questions

What is the interrupting capacity of this breaker at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

What are the physical dimensions of 3VA2110-5HL32-0KL0?

Depth 86 mm, width 105 mm, height 181 mm.

Does this breaker require derating at high ambient temperatures?

No — it holds 100 A continuous from 40 °C through 70 °C with no derating.

What auxiliary switches and releases are included?

2 auxiliary switches, 1 trip alarm switch, 1 electrical alarm switch (HQ type), and a shunt trip release. No undervoltage release or ground-fault monitoring.

Where can I buy 3VA2110-5HL32-0KL0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or firm lead time published here.

MPN
3VA2110-5HL32-0KL0