MPN3VA2110-5HL36-0AC0

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2110-5HL36-0AC0, 3-pole, 100 A, 187 kA at 240 V AC, ETU320 electronic trip unit, IP40 front, depth 86 mm, width 105 mm, height 181 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HL36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-5HL36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-5HL36-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.10 W
3VA2110-5HL36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2110-5HL36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HL36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-5HL36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HL36-0AC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2110-5HL36-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, with a line-protection ETU320 electronic trip unit. Its interrupting capacity hits 187 kA at 240 V AC and 121 kA at 415 V AC — numbers that put it squarely in high-fault-duty panels where upstream SCCR headroom is critical.

The 187 kA at 240 V AC and 121 kA at 415 V AC are the maximum fault currents this MCCB can safely interrupt without welding contacts or rupturing the case. That level of interrupting capacity is typical for main feeders in industrial switchboards where the available fault current from the transformer can exceed 100 kA. At 690 V the rating drops to 4.25 kA — still enough for most motor-circuit faults, but the real headroom lives at the lower voltages. The 100 A continuous rating holds flat from 40 °C to 50 °C (–). Above that, derating kicks in: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C.

The MCCB measures 105 mm wide, 181 mm high, and 86 mm deep. The 2 HQ auxiliary switches provide status feedback for the PLC or HMI without a separate contactor block.

That adjustability lets the panel designer achieve full selectivity with downstream 100 A or smaller breakers, so a fault on a branch doesn't take out the main feeder. The 800 V rated insulation voltage covers 480 V and 600 V class systems with margin.

Frequently asked questions

Who supplies 3VA2110-5HL36-0AC0 and how is it quoted for volume purchases?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is listed here.

What is 3VA2110-5HL36-0AC0's listed depth?

The depth is 86 mm.

What is 3VA2110-5HL36-0AC0's listed width?

The width is 105 mm.

Will 3VA2110-5HL36-0AC0 drop into a panel specified around 3VA1110-5EE32-0JA0 without rewiring?

The 3VA2110-5HL36-0AC0 is a higher-fault-duty variant (187 kA vs the 3VA1110's typical 65–100 kA range) and uses an ETU320 electronic trip unit versus the 3VA1110's thermal-magnetic or basic electronic trip. The mounting footprint and terminal spacing are similar across the 3VA family, so it will physically fit the same DIN-rail or backplate location, but the trip curve and settings differ — verify coordination with the existing downstream breakers before swapping.

MPN