Siemens 3VA2110-5HL36-0AE0 SENTRON MCCB, 100A, 187kA at 240V

MPN3VA2110-5HL36-0AE0

Siemens SENTRON 3VA2110-5HL36-0AE0, molded case circuit breaker, 3-pole, 100A, ETU320 electronic trip, 187 kA at 240 V, 4 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HL36-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-5HL36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-5HL36-0AE0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.10 W
3VA2110-5HL36-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2110-5HL36-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HL36-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-5HL36-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HL36-0AE0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

No undervoltage release, no shunt trip, no ground-fault module — this is a straight line-protection breaker with the aux contacts factory-fitted.

The breaker holds full 100 A up to 50 °C ambient; at 55 °C it derates to 96.25 A, at 60 °C to 92.5 A, at 65 °C to 88.75 A, and at 70 °C to 85 A. In a sealed enclosure or a hot machine cabinet, that derating curve tells you whether you need to step up to the next frame or add ventilation. The 105 mm width and 86 mm depth fit standard Siemens 3VA panel cutouts and busbar centers — no re-drilling if you're swapping a 3VA1 or earlier 3VL.

Frequently asked questions

Where can I buy 3VA2110-5HL36-0AE0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is 3VA2110-5HL36-0AE0's listed depth and width?

Depth is 86 mm; width is 105 mm. Height is 181 mm.

Will 3VA2110-5HL36-0AE0 drop into a panel that was specified around 3VA1110-5EE32-0JA0 without rewiring?

Both are 3-pole SENTRON MCCBs on the same 105 mm width footprint, so the mechanical cutout and busbar centers are the same. However, the 3VA2110 carries an ETU320 electronic trip unit and 187 kA interrupting capacity, while the 3VA1110 uses a different trip system and lower breaking capacity — verify the trip curve and SCCR coordination before swapping.

MPN
3VA2110-5HL36-0AE0