Siemens 3VA2110-5HL36-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HL36-0AF0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5HL36-0AF0

Siemens SENTRON 3VA2110-5HL36-0AF0, 3-pole molded case circuit breaker, 100 A continuous rating, 187 kA interrupting at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HL36-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2110-5HL36-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5HL36-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5HL36-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HL36-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-5HL36-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HL36-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2110-5HL36-0AF0 — 100 A MCCB, Line Protection

The Siemens SENTRON 3VA2110-5HL36-0AF0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range of 40 °C to 70 °C, meaning no derating is needed in a warm enclosure — it holds 100 A at every point in that span. This MCCB is designed for line protection, not motor or feeder backup — it protects the cable or busbar directly downstream of the breaker, tripping on overload and short-circuit without the intentional delay a motor-circuit protector would carry.

Interrupting Capacity — What the Ratings Mean

The interrupting capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. At 240 V this breaker can safely clear a fault up to 187 kA without rupturing — that is the SCCR the breaker itself contributes to the panel label. At 690 V the capacity drops to 3.7 kA, so on a 690 V system the available fault current must be verified against that lower figure. Rated insulation voltage is 800 V, which governs the dielectric withstand of the internal clearances — the breaker is physically rated for the 690 V system voltage class, but the interrupting rating at that voltage is the binding constraint for coordination studies.

Fit and Panel Integration

Dimensions are 181 mm high, 105 mm wide, 86 mm deep. The 86 mm depth is the dimension from the mounting surface to the front of the breaker — relevant when the panel depth is tight and the door clearance or gland-plate space is limited. The breaker includes one auxiliary switch and one trip alarm switch (HQ design) for remote status indication — the auxiliary follows the breaker position (ON/OFF), the trip alarm signals only when the breaker has tripped on fault, not when manually switched off. No undervoltage release, no voltage trigger, no ground-fault monitoring, and no communication function are fitted on this variant — it is a plain thermal-magnetic line-protection breaker with basic auxiliary contacts.