Siemens 3VA2110-5HL36-0BL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HL36-0BL0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5HL36-0BL0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2110-5HL36-0BL0, 3-pole, 100 A rated current, 187 kA breaking capacity at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5HL36-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2110-5HL36-0BL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W

Protection & Trip Unit

3VA2110-5HL36-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5HL36-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5HL36-0BL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2110-5HL36-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5HL36-0BL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens 3VA2110-5HL36-0BL0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current across the full operating temperature range from -25 °C to 70 °C — no derating needed up to 70 °C ambient, which simplifies panel design in warm enclosures or near other heat sources. It's a 3-pole line-protection device, meaning it's built for feeder and distribution duty rather than motor protection — you'd use it on the incoming side of a panel or to protect a busway, not across a motor starter. The breaking capacity hits 187 kA at 240 V AC, 121 kA at 415/440 V, and still manages 75.6 kA at 500 V — high enough to sit behind a large transformer without worrying about cascading failure upstream.

What the ratings mean for your panel

The 100 A rating holds flat from 40 °C through 70 °C — no thermal derating curve to chase. That's unusual for a molded case breaker this compact (181 × 105 × 86 mm) and means you don't have to oversize the frame for a hot panel. The auxiliary switch block ships with 2 auxiliary switches, 1 trip alarm, and 1 electrical alarm switch — that's enough for remote status on a feeder breaker without adding a separate accessory module. It includes an undervoltage release (UVR) as part of the design — that's the coil that drops the breaker if control power fails, common in safety circuits and emergency-stop chains.

Mounting and integration

At 105 mm wide, it fits a standard 3-pole MCCB footprint — no special adapter plate needed for most panelboards or switchgear cubicles. Depth of 86 mm (3.39 in) means it clears most shallow enclosures; height of 181 mm (7.13 in) is typical for this frame class.

MPN
3VA2110-5HL36-0BL0