Siemens 3VA2110-5HL36-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HL36-0JC0 MCCB, 100 A, 187 kA at 240 V

MPN3VA2110-5HL36-0JC0

Siemens SENTRON 3VA2110-5HL36-0JC0, molded case circuit breaker, 3-pole, 100 A continuous, 187 kA interrupting at 240 V, line protection design with shunt trip and 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5HL36-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2110-5HL36-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-5HL36-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5HL36-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5HL36-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-5HL36-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5HL36-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What the ratings mean for fit

The Siemens SENTRON 3VA2110-5HL36-0JC0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling. That flat thermal curve is unusual; most MCCBs start derating above 40 °C. For the panel builder, it means the 100 A rating holds in a warm enclosure without oversizing the frame. Interrupting capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. At 415 V — common for European industrial distribution — the 121 kA rating covers most transformer-fed fault levels without requiring current-limiting fuses upstream. The steep drop to 3.7 kA at 690 V means this frame is not intended for 690 V main feeders; it is a line-protection device for 400 V class systems. Dimensions are 181 mm high, 105 mm wide, 86 mm deep. The 105 mm width for a 3-pole 100 A frame is standard for Siemens SENTRON MCCBs; it fits the same panel cutout and DIN-rail footprint as other 3VA2 frames. The 86 mm depth leaves clearance for rear-connected busbars or a shunt-trip wiring channel.

Built-in accessories and lifecycle

This breaker ships with a shunt trip (STL) release and two HQ-rated auxiliary switches integrated — no separate add-on modules to order or install. The shunt trip allows remote tripping from a PLC or emergency-stop circuit; the auxiliary switches provide status feedback (open/closed/tripped) to the control system. There is no undervoltage release, no ground-fault monitoring, and no communication function on this variant.

Deployment context

Designed for line protection in 400 V class distribution panels — feeding downstream branch circuits, motor control centers, or sub-distribution boards. The 100 A frame with 187 kA interrupting capacity at 240 V makes it suitable for high-fault service-entrance applications where the available short-circuit current is substantial. Mounts on a DIN rail or panel-mount plate in a standard enclosure; the 86 mm depth keeps the breaker within typical 200 mm deep cabinet profiles.

Frequently asked questions

What is the interrupting capacity of 3VA2110-5HL36-0JC0 at 415 V?

121 kA at 415 V, which covers most industrial transformer-fed fault levels without requiring upstream current-limiting fuses.

Does the 100 A rating derate at higher ambient temperatures?

No — the 100 A continuous rating holds flat from 40 °C through 70 °C. No derating is needed within that range.

What accessories are built into this breaker?

A shunt trip (STL) release for remote tripping and two HQ-rated auxiliary switches for status feedback. No undervoltage release, ground-fault monitoring, or communication module is included.

Where can I buy 3VA2110-5HL36-0JC0 and get current pricing?

Sourced to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ — submit one through the storefront for a firm quote.

MPN