Skip to main content
Siemens 3VA2110-5HN32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HN32-0KA0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5HN32-0KA0

Siemens SENTRON 3VA2110-5HN32-0KA0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, line protection, with shunt trip release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HN32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HN320AA0
3VA2110-5HN32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5HN32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5HN32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HN32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-5HN32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HN32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-5HN32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — meaning no derating is needed in a warm enclosure. The breaking capacity at 240 V is 187 kA, at 415/440 V it's 121 kA, and at 500 V it's 75.6 kA; at 690 V it drops to 3.7 kA. For a 480 V distribution panel, the 75.6 kA SCCR at 500 V gives you a solid margin above typical 65 kA or 100 kA requirements.

Physical integration

The 3VA2110-5HN32-0KA0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits most SENTRON panelboards and switchgear cubicles without re-drilling. Maximum power loss is 10 W, so ventilation in a sealed enclosure is manageable.

Frequently asked questions

Where can I buy 3VA2110-5HN32-0KA0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability; both are confirmed at quote time.

What is the breaking capacity of this MCCB at 240 V?

The breaking capacity at 240 V is 187 kA. At 415/440 V it's 121 kA, at 500 V it's 75.6 kA, and at 690 V it's 3.7 kA.

Does this breaker have a shunt trip?

Yes, the auxiliary release is a shunt trip (STL) — it allows remote tripping via a control voltage.

MPN
3VA2110-5HN32-0KA0