Skip to main content
Siemens 3VA2110-5HN36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HN36-0AC0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5HN36-0AC0

Siemens SENTRON 3VA2110-5HN36-0AC0, molded case circuit breaker, 3-pole, 100 A, 187 kA interrupting at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5HN36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2110-5HN36-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-5HN36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5HN36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5HN36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-5HN36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5HN36-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens SENTRON 3VA2110-5HN36-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, designed for line protection in distribution panels. Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — so it handles high-fault scenarios on the low-voltage side while still clearing moderate faults at higher voltages. Rated insulation voltage is 800 V, meaning it's built for 690 VAC systems with margin. The breaker carries two HQ auxiliary switches (form C) for status feedback to a PLC or annunciator panel.

Sizing and thermal performance

The 100 A rating holds flat from 40 °C all the way to 70 °C ambient — no derating needed in a warm enclosure, which is unusual for an MCCB this size. Maximum power loss is 10 W, so it won't cook neighboring components in a dense panel.

Physical fit and panel integration

Dimensions are 181 mm high, 105 mm wide, 86 mm deep — standard MCCB footprint for a 100 A frame, mounts on a DIN rail or direct panel. No undervoltage release, no ground-fault monitoring, no communication module on this variant — it's a straight thermal-magnetic line-protection breaker with aux contacts.

Frequently asked questions

Does this breaker include a trip indicator or undervoltage release?

No trip indicator, no undervoltage release, no ground-fault monitoring on this variant. It does include two HQ auxiliary switches.

MPN
3VA2110-5HN36-0AC0