Skip to main content
Siemens 3VA2110-5HN36-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HN36-0AE0 SENTRON MCCB, 100 A, 3-Pole

MPN3VA2110-5HN36-0AE0

Siemens SENTRON 3VA2110-5HN36-0AE0, molded case circuit breaker, 3-pole, 100 A rated continuous current, line protection design, 86 mm depth, 105 mm width, 181 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HN36-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-5HN36-0AE0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5HN36-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5HN36-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HN36-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-5HN36-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HN36-0AE0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2110-5HN36-0AE0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, carrying a 187 kA interrupting capacity at 240 V.

Interrupting capacity and what it means for your panel

At 415 V the rating drops to 121 kA, and at 690 V it falls to 3.7 kA. That steep drop at 690 V is typical for a 100 A frame; if your panel feeds a 690 V line-up, verify the available fault current is under 3.7 kA or step to a higher-frame breaker.

Physical fit and integration

The auxiliary switch block is a separate order — the base breaker ships without a trip indicator or undervoltage release.

Frequently asked questions

Who supplies 3VA2110-5HN36-0AE0 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for volume pricing.

What is the interrupting capacity of 3VA2110-5HN36-0AE0 at 240 V?

The interrupting capacity is 187 kA at 240 V. At 415 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it is 3.7 kA.

Does 3VA2110-5HN36-0AE0 include a trip indicator or undervoltage release?

No — it ships without a trip indicator and without an undervoltage release. Auxiliary switches are ordered separately.

MPN
3VA2110-5HN36-0AE0