Skip to main content
Siemens 3VA2110-5HN36-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HN36-0AJ0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA2110-5HN36-0AJ0

Siemens SENTRON 3VA2110-5HN36-0AJ0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, ETU350 electronic trip unit, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5HN36-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-5HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2110-5HN36-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.10 W
3VA2110-5HN36-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2110-5HN36-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HN36-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-5HN36-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HN36-0AJ0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

MCCB for main or feeder protection — 100 A, 187 kA SCCR

The Siemens SENTRON 3VA2110-5HN36-0AJ0 is a 3-pole molded case circuit breaker rated for 100 A continuous at 40 °C, with a maximum breaking capacity of 187 kA at 240 V AC. At 415 V and 440 V it still holds 121 kA, and at 690 V it drops to 4.25 kA, so the voltage-dependent curve governs where you place it in the distribution. Power loss maxes at 10 W — negligible for panel thermal budget but worth noting if you pack breakers tight.

Auxiliary contacts and release options

No undervoltage release, no shunt trip, no ground-fault module on this variant. The basic switch base is 3VA2110-5HN36-0AA0 if you ever need the bare breaker without auxiliaries.

Frequently asked questions

What is the breaking capacity of 3VA2110-5HN36-0AJ0 at 240 V?

187 kA at 240 V AC, derating to 121 kA at 415/440 V, 79 kA at 500 V, and 4.25 kA at 690 V.

What trip unit does this breaker use?

ETU350 electronic trip unit — adjustable overload and short-circuit protection with a trip indicator on the front.

Where can I buy 3VA2110-5HN36-0AJ0?

Sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

Will 3VA2110-5HN36-0AJ0 drop into a panel designed for 3VA1010-2ED36-0AC0?

The 3VA2 frame is physically larger than the 3VA1 frame — 105 mm wide vs 55 mm for the 3VA1 3-pole. It will not fit the same mounting footprint without panel modifications.

MPN