Skip to main content
Siemens 3VA2110-5HN36-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5HN36-0DC0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA2110-5HN36-0DC0

Siemens SENTRON 3VA2110-5HN36-0DC0, molded case circuit breaker, 3-pole, 100 A rated continuous current, 187 kA at 240 V, ETU350 electronic trip unit, undervoltage release, 2 HQ auxiliary switches, 105 x 181 x 86 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5HN36-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-5HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2110-5HN36-0DC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.12.5 W

Protection & Trip Unit

3VA2110-5HN36-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2110-5HN36-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5HN36-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-5HN36-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5HN36-0DC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What the ratings mean for fit

The Siemens SENTRON 3VA2110-5HN36-0DC0 is a 3-pole molded case circuit breaker (MCCB) in the 3VA2 frame, rated for line protection. Its 100 A continuous current (Iu) holds through 50 °C ambient; above that it derates to 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C — so if the panel runs hot, size the breaker for the actual load at your ambient, not the nameplate 100 A. The interrupting ratings climb with voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. That 187 kA figure at 240 V is the headline — it handles high-fault utility feeds without cascading upstream, provided the available fault current at the panel doesn't exceed that level. The ETU350 electronic trip unit gives adjustable overload and short-circuit protection curves, plus an integrated undervoltage release (UVR) that drops the breaker when control voltage is lost — useful for safety circuits or emergency-stop chains that need a hard shunt trip on power loss. Rated insulation voltage is 800 V, so it's comfortable on 480/277 V and 600 V industrial systems. It ships with two HQ auxiliary switches (form C) for status feedback to a PLC or annunciator panel.

Mounting and integration

The 3VA2110-5HN36-0DC0 measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard 3-pole MCCB footprint that drops into SENTRON panelboards or standalone DIN-rail adapters. The 86 mm depth means it clears most shallow enclosures; verify the back-panel clearance if you're retrofitting into a tight bucket. The auxiliary trip coil (3VA9608-0BB25) is factory-installed; no field wiring of a separate shunt trip module needed. The undervoltage release is wired to a control circuit — it holds the breaker closed as long as voltage is present, and trips on dropout below the release threshold.

Lifecycle and sourcing

The 3VA2 frame is the successor to the older 3VL series, with a slimmer profile and the ETU electronic trip family. If you're replacing a 3VL breaker in an existing panel, check the mounting footprint and bus-bar spacing — the 3VA2 uses the same 105 mm width but the depth and terminal layout differ.

Frequently asked questions

What is the closest functional second-source for 3VA2110-5HN36-0DC0?

The 3VA2010-5HL36-0BE0 is a sibling in the same SENTRON 3VA2 family, but it carries a different electronic trip unit and auxiliary configuration. The 3VA2110-5HN36-0DC0 has the ETU350 release and an integrated undervoltage release; the 3VA2010-5HL36-0BE0 uses a different trip curve and lacks the UVR. They share the same frame size and 100 A rating, but the trip unit and auxiliaries are not drop-in interchangeable — verify the protection settings and control wiring before substituting.

What are the key ratings for 3VA2110-5HN36-0DC0?

Rated continuous current 100 A, interrupting capacity 187 kA at 240 V, 121 kA at 415 V, 79 kA at 500 V, 4.25 kA at 690 V. Rated insulation voltage 800 V. ETU350 electronic trip unit with undervoltage release. Two HQ auxiliary switches. Dimensions 105 x 181 x 86 mm.

How do I get pricing and availability for 3VA2110-5HN36-0DC0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and lead time are confirmed at quote time.

MPN
3VA2110-5HN36-0DC0