Specifications

3VA2110-5HN36-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-5HN36-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5HN36-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5HN36-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5HN36-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-5HN36-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5HN36-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2110-5HN36-0JC0 is a 3-pole molded case circuit breaker rated 100 A continuous across the full ambient range from 40 °C to 70 °C — no derate curve to chase. Breaking capacity hits 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. Designed for line protection, it ships with a factory-fitted shunt trip (STL) and two HQ auxiliary switches.

Shunt trip (STL) is fitted ex-works — remote trip via a control signal is ready to wire. Two HQ auxiliary switches give status feedback for the PLC or indicator lamps.

Panel footprint

Mounts in a standard panel cutout. The 3-pole frame with shunt trip and aux switches fits within the standard 3VA2 envelope — no extra width for the accessories.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

187 kA at 240 V. At 415/440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it is 3.7 kA.

Does this breaker include a shunt trip or auxiliary contacts?

Yes. Factory-fitted with a shunt trip (STL) for remote tripping and two HQ auxiliary switches for status feedback.

Where can I buy the 3VA2110-5HN36-0JC0?

Sourced to order against an RFQ through independent distribution. Submit a request for current pricing and lead time.

MPN