Siemens 3VA2110-5HN42-0DA0 Circuit Breaker, 100A, 55kA @ 415

MPN3VA2110-5HN42-0DA0

Siemens 3VA2 series, IEC frame 160 MCCB, 4-pole, breaking capacity class M 55kA @ 415V, ETU350 LSI trip unit, In=100A, with undervoltage release 208-230 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this 3VA2 MCCB carries

The Siemens 3VA2110-5HN42-0DA0 is a 4-pole IEC frame 160 molded case circuit breaker with a 55 kA breaking capacity at 415 V (class M), rated at In = 100 A. It uses an ETU350 LSI electronic trip unit with adjustable overload protection Ir = 40…100 A, short-circuit protection Isd = 1.5…10 × Ir, and instantaneous protection Ii = 12 × In. The neutral conductor protection is adjustable (OFF, 50%, 100%). The unit ships with a factory-fitted undervoltage release rated 208–230 V AC, 50/60 Hz, and a nut keeper kit for panel mounting.

What the ratings mean for panel fit

The 55 kA Icu at 415 V places this breaker in the medium breaking capacity class (class M), sized for industrial distribution panels where fault currents can reach that level — typical for transformer-fed switchboards in a factory. The ETU350 LSI trip unit provides selective coordination with downstream breakers: the long-time (L) band handles overloads, the short-time (S) band with adjustable delay allows downstream devices to clear a fault first, and the instantaneous (I) band catches high-magnitude faults. The adjustable neutral protection (OFF, 50%, 100%) suits 4-wire systems where neutral current monitoring is required by local code.

Undervoltage release integration

The integrated undervoltage release (208–230 V AC, 50/60 Hz) automatically trips the breaker when control voltage drops below its dropout threshold — a standard requirement for emergency-stop circuits and safety disconnects in machinery. The release is factory-installed, so no field wiring of a separate accessory is needed.

Frequently asked questions

Where can I buy 3VA2110-5HN42-0DA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of this MCCB?

The breaking capacity is 55 kA at 415 V (IEC class M), suitable for industrial distribution panels with high prospective fault currents.

What trip unit does the 3VA2110-5HN42-0DA0 use?

It uses an ETU350 LSI electronic trip unit with adjustable overload (Ir = 40…100 A), short-time (Isd = 1.5…10 × Ir), and instantaneous (Ii = 12 × In) protection, plus adjustable neutral protection.