Skip to main content
Siemens 3VA2110-5JQ32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5JQ32-0AC0 SENTRON MCCB, 100 A, 3-Pole, ETU5

MPN3VA2110-5JQ32-0AC0

Siemens SENTRON 3VA2110-5JQ32-0AC0, molded case circuit breaker, 3-pole, 100 A, ETU560 electronic trip unit, line protection, 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5JQ32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-5JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2110-5JQ32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-5JQ32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560

Construction & Connection

3VA2110-5JQ32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5JQ32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-5JQ32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5JQ32-0AC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this breaker is and where it fits

The Siemens 3VA2110-5JQ32-0AC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current, fitted with an ETU560 electronic trip unit for line protection. It carries a 187 kA interrupting rating at 240 V, dropping to 121 kA at 415/440 V, 79 kA at 500 V, and 4.25 kA at 690 V — so the available fault current at the panelboard determines which voltage column you read. This is a current-production part, actively manufactured.

Thermal derating and real-world current

The 100 A rating holds up to 50 °C ambient. Above that it steps down: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. If your panel interior runs hot — say a packed enclosure with drives — the 70 °C figure is the one to size against. Maximum power loss is 10 W.

Trip unit and monitoring

The ETU560 is an electronic overcurrent release with communication capability. Ground-fault monitoring uses summation-current formation on the L-conductor. The breaker ships with two HQ auxiliary switches; no undervoltage release or voltage trigger is fitted. The front face carries IP40 protection — fine for a closed panel, not for washdown exposure.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm high, 86 mm deep. That 105 mm width is the standard 3-pole MCCB footprint for this class — it occupies three 35 mm DIN spaces if base-mounted, though the SENTRON 3VA series typically bolts to a mounting plate rather than snapping onto DIN rail. Verify the bus-bar drilling pattern against your existing panel layout; the depth leaves clearance for rear-connected lugs.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V.

What trip unit does the 3VA2110-5JQ32-0AC0 use?

It uses an ETU560 electronic overcurrent release with communication function and summation-current ground-fault monitoring.

Where can I buy the 3VA2110-5JQ32-0AC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 3VA2110-5JQ32-0AC0 drop into a panel specified for 3VA1010-2ED32-0JA0?

Both are 3-pole SENTRON MCCBs in the same 105 mm width footprint, so the physical fit is the same. The key difference is the trip unit: the 3VA2110 carries an ETU560 electronic release with communication, while the 3VA1010 uses a different release. Verify the control wiring and any auxiliary-contact scheme before swapping — the auxiliary contact version on this unit is 2 HQ switches.

MPN
3VA2110-5JQ32-0AC0