Siemens 3VA2110-5KP32-0AD0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5KP32-0AD0

Siemens SENTRON 3VA2110-5KP32-0AD0, molded case circuit breaker, 3-pole, 100 A continuous, line protection, 187 kA breaking at 240 V, with communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5KP32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-5KP32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5KP32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5KP32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5KP32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-5KP32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5KP32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its 187 kA interrupting capacity at 240 V AC handles high-fault scenarios typical in industrial feeder circuits, while the 121 kA rating at 415 V and 440 V covers common European and North American distribution voltages. This MCCB carries a communication function, meaning it can integrate with plant monitoring or energy management systems — useful for a pulp mill or continuous process line where you want breaker status and load data back in the DCS without a separate I/O run.

At 500 V it's 75.6 kA, and at 690 V it drops to 3.7 kA.

Thermal performance across the panel ambient range

That's a solid spec for a mill MCC room or a hot rooftop panel where summer ambients push 55 °C. Power loss is 10 W maximum, so heat buildup inside a compact panel is manageable.

Physical fit and auxiliary configuration

The breaker ships with three auxiliary switches (HQ type) fitted, so you get remote status indication without ordering add-on modules separately.

Frequently asked questions

What is the breaking capacity of 3VA2110-5KP32-0AD0 at 415 V?

At 415 V AC the interrupting rating is 121 kA. The same rating applies at 440 V. At 240 V it is 187 kA, and at 690 V it is 3.7 kA.

Where can I buy 3VA2110-5KP32-0AD0 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

MPN