Skip to main content
Siemens 3VA2110-5KP32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5KP32-0BH0 SENTRON MCCB, 100 A, 150-1200 A T

MPN3VA2110-5KP32-0BH0

Siemens SENTRON 3VA2110-5KP32-0BH0, molded case circuit breaker, 3-pole, 100 A continuous, adjustable thermal-magnetic trip 150-1200 A, 187 kA at 240 V, with undervoltage release and communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5KP32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2110-5KP32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W

Protection & Trip Unit

3VA2110-5KP32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5KP32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5KP32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2110-5KP32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5KP32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2110-5KP32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous at 40 °C, with an adjustable thermal-magnetic trip unit covering 150 A to 1 200 A. It's designed for line protection in distribution panels and switchgear. The interrupting ratings are substantial: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. That SCCR headroom means it can handle high-fault-capacity mains without cascading upstream. It carries an undervoltage release (UVR) and a communication function, plus two auxiliary switches and one trip alarm switch. The basic switch module is order code 3VA21105KP320AA0.

Sizing and thermal performance

The continuous current rating holds at 100 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That simplifies panel design in warm enclosures or near other heat sources. Maximum power loss is 12.5 W, which is modest for a 100 A frame. The operating temperature range spans -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep. That 105 mm width is the standard 3-pole MCCB footprint for this frame size — it drops into existing SENTRON panel layouts without re-drilling. The trip indicator is present, and the unit has no voltage-trigger function. Ground-fault monitoring is not included on this variant.

Frequently asked questions

How do I get current pricing and availability for 3VA2110-5KP32-0BH0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock status are confirmed at quote time.

What are the key ratings for this MCCB?

Continuous current is 100 A (no derating up to 70 °C). The adjustable trip range is 150 A to 1 200 A. Interrupting capacity reaches 187 kA at 240 V and 121 kA at 415 V.

Will 3VA2110-5KP32-0BH0 drop into a panel specified around 3VA1110-5EF32-0AM0?

The 3VA2110 frame is physically larger than the 3VA1110 — the 105 mm width is the same, but the 181 mm height and 86 mm depth differ. It will not drop into a panel cutout designed for the 3VA1110 without checking the mounting footprint and bus bar alignment.

MPN
3VA2110-5KP32-0BH0