Siemens 3VA2110-5KP32-0JC0 — Molded Case Circuit Breakers (MCCB)

3VA2110-5KP32-0JC0 SENTRON MCCB, 100 A, 3-Pole, Line Protect

MPN3VA2110-5KP32-0JC0

Siemens SENTRON 3VA series molded case circuit breaker, order code 3VA2110-5KP32-0JC0, 3-pole, 100 A continuous rating, line protection design, 187 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5KP32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2110-5KP32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-5KP32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5KP32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5KP32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-5KP32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5KP32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2110-5KP32-0JC0 — 100 A MCCB for Line Protection

The Siemens SENTRON 3VA2110-5KP32-0JC0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. It is designed specifically for line protection, meaning it guards cables and busbars against overload and short-circuit, not motor or generator circuits. The interrupting capacity reaches 187 kA at 240 V and still holds 121 kA at 415 V and 440 V, which gives substantial fault-current headroom for most industrial distribution panels. At 690 V the rating drops to 3.7 kA, so verify the available fault current if deploying on a 690 V line.

What the Ratings Mean for Panel Integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. The unit ships with a shunt trip (STL) auxiliary release and two HQ auxiliary switches, so remote tripping and status feedback are built in without adding external modules. A communication function is included, which on the 3VA platform typically means a modular communication-capable trip unit; confirm the protocol interface (PROFIBUS, PROFINET, or Modbus) when specifying the system integration.

Selectivity and Coordination Note

The 100 A frame with a 1 200 A maximum and 150 A minimum setting range (on the trip unit) gives the panel designer flexibility to coordinate downstream breakers. The 187 kA SCCR at 240 V means this breaker can be installed ahead of a 65 kA-rated downstream panel without cascading failure — a common requirement for service-entrance or main-switchboard positions. At 415 V the 121 kA rating still covers most industrial transformer secondaries.

Frequently asked questions

What is the breaking capacity of 3VA2110-5KP32-0JC0 at 240 V?

187 kA at 240 V. At 415 V and 440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it drops to 3.7 kA.

Does 3VA2110-5KP32-0JC0 require derating at high ambient temperatures?

No derating is needed up to 70 °C — the continuous current rating stays at 100 A from 40 °C through 70 °C.

What auxiliary switches and releases come with this MCCB?

It includes two HQ auxiliary switches and a shunt trip (STL) release. The supplied basic switch is 3VA21105KP320AA0.

Where can I buy 3VA2110-5KP32-0JC0 and how is it quoted?

We source this part through the Siemens distribution channel and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
3VA2110-5KP32-0JC0