Skip to main content
Siemens 3VA2110-5KP32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5KP32-0JH0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5KP32-0JH0

Siemens SENTRON molded case circuit breaker, 3VA2110-5KP32-0JH0, 100 A, 3-pole, line protection, 187 kA interrupting at 240 V, with shunt trip and communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-5KP32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2110-5KP32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-5KP32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-5KP32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-5KP32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2110-5KP32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-5KP32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-5KP32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel sizing in warm enclosures. Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — figures that cover most low-voltage fault scenarios in industrial distribution. Designed for line protection, this MCCB includes a shunt trip (STL) release for remote opening, two auxiliary switches plus one trip alarm switch HQ for status feedback, and a communication function for integration into higher-level monitoring systems.

Integration Notes

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — fits standard SENTRON panel cutouts and busbar systems for 3-pole MCCBs. The shunt trip release allows remote tripping from a PLC or emergency-stop circuit; the auxiliary and alarm switches provide status feedback without additional interface relays. A trip indicator and voltage trigger are present on the breaker face, aiding quick fault identification during commissioning or troubleshooting.

Frequently asked questions

Will 3VA2110-5KP32-0JH0 drop into a panel specified for 3VA1110-5EF32-0AM0?

The 3VA2110-5KP32-0JH0 shares the same 3-pole SENTRON platform dimensions (105 mm wide, 181 mm high, 86 mm deep) and busbar pitch as the 3VA1110 series, so it will physically fit the same cutout and busbar system without panel modification.

MPN
3VA2110-5KP32-0JH0