Skip to main content
Siemens 3VA2110-5KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5KQ42-0AA0 SENTRON MCCB, 100 A, 4-Pole, 187

MPN3VA2110-5KQ42-0AA0
Active

Siemens SENTRON 3VA2110-5KQ42-0AA0, molded case circuit breaker, 4-pole, 100 A continuous, 187 kA breaking at 240 V, line protection design with communication and ground-fault monitoring.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-5KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2110-5KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-5KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

SENTRON 3VA2110-5KQ42-0AA0 — 100 A 4-Pole MCCB for Line Protection

Maximum power loss is 10 W — useful to know for thermal management inside a sealed enclosure.

Breaking Capacity Across Voltages — What the Numbers Mean

Breaking capacity drops as voltage rises: 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. For a 400 V distribution board, the 121 kA figure is well above typical utility fault levels (often 25–50 kA), so this breaker gives generous margin. At 690 V, the 3.7 kA limit means it's not suitable for high-fault industrial 690 V mains; you'd need a larger frame or a current-limiting design.

Thermal Performance — Flat Derating to 70 °C

That's unusual for an MCCB; many competitors start derating above 40 °C. The flat thermal curve simplifies panel design: you don't have to oversize the breaker for a warm enclosure or derate for a hot machine room.

Panel Integration — Dimensions and Mounting

Dimensions: 181 mm height, 140 mm width, 86 mm depth. Depth of 86 mm means it clears most standard enclosure backplates without a sub-panel. Mounting is via screw-clamp to the backplate; no DIN rail for this frame size.

Trip Unit and Adjustment Range

The trip unit is adjustable from 150 A minimum to 1 200 A maximum — that is the magnetic/instantaneous pickup range, not the continuous current. The continuous rating is fixed at 100 A.

Frequently asked questions

Does the 3VA2110-5KQ42-0AA0 include ground-fault monitoring?

Yes, it has ground-fault monitoring via summation current formation on the L+N conductor. It also includes a communication function for remote monitoring.

MPN
3VA2110-5KQ42-0AA0