Skip to main content
Siemens 3VA2110-5MN36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5MN36-0AA0 SENTRON MCCB, 100 A, 3-Pole, Moto

MPN3VA2110-5MN36-0AA0
Active

Siemens SENTRON molded case circuit breaker, 3VA2110-5MN36-0AA0, 3-pole, 100 A rated continuous current, motor protection design, adjustable trip class 10A/10E/20E.

$246.38Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5MN36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-5MN36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5MN36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5MN36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5MN36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-5MN36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5MN36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2110-5MN36-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed specifically for motor protection, with a rated continuous current of 100 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling. Its 3-pole construction and motor protection design mean it's built for three-phase motor branch circuits, with phase failure detection built in and an adjustable trip class that lets you match the overload curve to the motor's thermal withstand: selectable between 10A, 10E, and 20E classes.

The interrupting ratings span the voltage range you'd expect in industrial distribution: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The rated insulation voltage of 800 V gives headroom for 690 V systems, and the maximum power loss of 10 W is modest for a 100 A frame — panel thermal rise stays manageable even in a crowded enclosure.

Dimensions are 105 mm wide by 181 mm high by 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without surprises. Operating temperature range is -25 °C to 70 °C, with storage from -40 °C to 80 °C, so it's suitable for unconditioned electrical rooms and outdoor-rated cabinets within those limits.

Frequently asked questions

How do I get current pricing and availability for 3VA2110-5MN36-0AA0?

Pricing and availability are confirmed at quote time against an RFQ through our independent distribution channel — submit a request and we'll source it to order.

What is the breaking capacity of this MCCB at 415 V?

121 kA at 415 V, which is the same rating as at 440 V — sufficient for high-fault industrial panels at that voltage level.

Does this breaker include phase failure protection?

Yes, phase failure detection is built into the design, which is standard for motor protection MCCBs to prevent single-phasing damage.

What trip classes are available on this unit?

The adjustable trip class can be set to 10A, 10E, or 20E, letting you match the overload curve to the motor's thermal withstand and starting characteristics.

MPN
3VA2110-5MN36-0AA0