Skip to main content
Siemens 3VA2110-5MN36-0KB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-5MN36-0KB0 SENTRON MCCB, 100 A, 3-Pole, 187

MPN3VA2110-5MN36-0KB0

Siemens SENTRON 3VA2110-5MN36-0KB0, molded case circuit breaker, 3-pole, 100 A rated current, 187 kA breaking capacity at 240 V, shunt trip release, 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-5MN36-0KB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21105MN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2110-5MN36-0KB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-5MN36-0KB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-5MN36-0KB0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-5MN36-0KB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-5MN36-0KB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-5MN36-0KB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-5MN36-0KB0 is a 3-pole molded case circuit breaker (MCCB) rated at 100 A continuously across the full 40 °C to 70 °C ambient range — no derating needed up to 70 °C, which simplifies panel layout in warm enclosures. Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 187 kA figure at 240 V means it can clear a high-fault bolted short circuit on the secondary of a large distribution transformer without the arc re-striking. Phase failure detection is onboard; undervoltage release and ground-fault monitoring are not included in this variant, so if those functions are required, specify a different order code or add external modules.

Maximum power loss is 10 W.

Frequently asked questions

Will the 3VA2110-5MN36-0KB0 drop into a panel specified around 5SQ2370-2YA05?

The 3VA2110-5MN36-0KB0 is a 3-pole MCCB with similar dimensions, but the 5SQ2370 series may lack the shunt trip and dual auxiliary switches this unit includes — verify the panel wiring diagram for those connections before substituting.

MPN
3VA2110-5MN36-0KB0