Skip to main content
Siemens 3VA2110-6HK36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HK36-0AA0 SENTRON MCCB, 100 A, 3-pole, ETU3

MPN3VA2110-6HK36-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2110-6HK36-0AA0, 100 A rated, 3-pole, ETU340 electronic overcurrent release, 242 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HK36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-6HK36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-6HK36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HK36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HK36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-6HK36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HK36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2110-6HK36-0AA0 is a SENTRON 3VA2 molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That 100 A holds flat through the entire operating band, so a panel designed for a 100 A feeder at 40 °C doesn't lose capacity when the enclosure warms to 65 °C. Its interrupting capacity hits 242 kA at 240 V and 187 kA at 415 V — numbers that place it squarely in high-fault-duty service, typically downstream of a transformer or on a large bus where available fault current exceeds 100 kA. The ETU340 electronic trip unit handles adjustable long-time, short-time, and instantaneous protection curves, so you're not locked into a fixed thermal-magnetic response. The 3-pole, 181 mm × 105 mm × 86 mm (H × W × D) footprint fits standard 3VA2 panel cutouts and bus-bar spacing. Front-face IP40 protection means it's suited for enclosed distribution boards where incidental tool or finger contact is the concern, not washdown environments.

No official successor has been published because none is needed; the 3VA2 platform remains the standard SENTRON MCCB line for distribution and feeder protection.

The 3VA2 mounts via four M6 screws on a rear panel or onto a mounting plate. Bus-bar connection uses standard MCCB lug kits — verify lug tunnel size against your cable or bus rating. The ETU340 draws 10 W maximum power loss, so account for that in enclosure thermal calculations, especially in a densely packed panel. Ground-fault monitoring is also absent on this build; specify a 3VA2 with the G option for that function.

MPN
3VA2110-6HK36-0AA0