Skip to main content
Siemens 3VA2110-6HL32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HL32-0AD0 SENTRON MCCB, 100 A, 150–1200 A

MPN3VA2110-6HL32-0AD0

Siemens SENTRON 3VA2110-6HL32-0AD0, molded case circuit breaker, 3-pole, 100 A continuous, adjustable overload range 150–1200 A, line protection design, 242 kA SCCR at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HL32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-6HL32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-6HL32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HL32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HL32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-6HL32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HL32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-6HL32-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range of 40 °C to 70 °C — no derating needed up to that ceiling. The adjustable overload trip covers 150 A to 1200 A, which means it can protect a feeder or a large motor branch where the load is well above the breaker's own frame rating. Short-circuit current ratings climb to 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — so it handles high-fault utility feeds without cascading upstream.

The basic switch assembly is order code 3VA21106HL320AA0.

Frequently asked questions

Where can I buy 3VA2110-6HL32-0AD0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is 3VA2110-6HL32-0AD0's listed depth?

The depth is 86 mm (3.39 in).

What is 3VA2110-6HL32-0AD0's listed width?

The width is 105 mm (4.13 in).

Will 3VA2110-6HL32-0AD0 drop into a panel specified around 3VA1020-2ED32-0DD0 without rewiring?

No direct footprint compatibility data is available between these two order codes. Both are SENTRON 3VA MCCBs, but the 3VA1020-2ED32-0DD0 is a different frame size and rating. Verify mounting dimensions and terminal spacing against your existing panel layout before substitution.

What compliance documentation does this brand provide for 3VA2110-6HL32-0AD0?

The evidence does not list specific compliance certificates. Siemens SENTRON MCCBs typically carry UL, CSA, CE, and IEC certifications; request the specific declaration for this order code at quote time.

MPN
3VA2110-6HL32-0AD0