Skip to main content
Siemens 3VA2110-6HL32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HL32-0AH0 SENTRON MCCB, 100 A, 3-Pole, 242

MPN3VA2110-6HL32-0AH0

Siemens SENTRON 3VA2110-6HL32-0AH0, 3-pole molded case circuit breaker, 100 A continuous rating, 242 kA at 240 V, 86 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HL32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2110-6HL32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-6HL32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HL32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HL32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-6HL32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HL32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-6HL32-0AH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at up to 70 °C ambient — no derating needed across the full temperature range. It is designed for line protection in distribution panels, with a breaking capacity of 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The 800 V rated insulation voltage suits it for 400 V and 690 V systems. The 86 mm depth, 105 mm width, and 181 mm height fit standard Siemens switchboard mounting.

At 415 V and 440 V the 187 kA rating still covers most industrial service-entrance and feeder applications. The drop to 3.7 kA at 690 V means this breaker is not intended for 690 V main feeders; it is a 240–500 V device. The 100 A continuous rating holds flat from 40 °C through 70 °C, so no thermal derating is needed even in a warm enclosure.

Frequently asked questions

Where can I buy 3VA2110-6HL32-0AH0 and how do I get a price?

The part is sourced to order against an RFQ through independent distribution. Submit a request for current availability and pricing.

What are the key ratings of 3VA2110-6HL32-0AH0?

It is a 3-pole MCCB rated 100 A continuous, with breaking capacities of 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. Insulation voltage is 800 V. Dimensions: 86 mm depth, 105 mm width, 181 mm height.

What is the depth of 3VA2110-6HL32-0AH0?

The depth is 86 mm (3.39 in).

What is the width of 3VA2110-6HL32-0AH0?

The width is 105 mm (4.13 in).

MPN