Siemens 3VA2110-6HL32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HL32-0CC0 SENTRON MCCB, 100 A, 3-Pole, 242

MPN3VA2110-6HL32-0CC0

Siemens SENTRON 3VA2110-6HL32-0CC0, molded case circuit breaker, 3-pole, 100 A continuous, 242 kA breaking at 240 V, line protection, undervoltage release, 86 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HL32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-6HL32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W
3VA2110-6HL32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HL32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HL32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-6HL32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HL32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-6HL32-0CC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, with a breaking capacity of 242 kA at 240 V AC — meaning it can safely interrupt fault currents up to that level without upstream cascading, critical for high-fault-capacity mains or sub-distribution boards. That 242 kA rating at 240 V drops to 187 kA at 415/440 V and 121 kA at 500 V; at 690 V the interrupting rating is 3.7 kA — a steep derate that matters if you're feeding a 690 V drive or transformer.

Line protection with undervoltage release — what's built in

No ground-fault monitoring, no communication function, and no voltage-trip or trip-indicator on the front. If you need ground-fault or Modbus, look at the 3VA2 variants with the appropriate option slot.

Production status and sourcing — still a current catalog part

For a BOM freeze or critical-spare holding, this is a safe pick: no imminent obsolescence risk.

Panel fit — dimensions and mounting

Frequently asked questions

Where can I buy 3VA2110-6HL32-0CC0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2110-6HL32-0CC0 at different voltages?

242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

Does 3VA2110-6HL32-0CC0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) as the auxiliary release type, plus two auxiliary switches.

MPN
3VA2110-6HL32-0CC0