Skip to main content
Siemens 3VA2110-6HL32-0CL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HL32-0CL0 SENTRON MCCB, 100 A, 3-Pole, 242

MPN3VA2110-6HL32-0CL0

Siemens SENTRON 3VA2110-6HL32-0CL0, molded case circuit breaker, 3-pole, 100 A continuous, adjustable trip 150–1200 A, breaking capacity 242 kA at 240 V, line protection, undervoltage release, 2 aux + 1 trip alarm + 1 electrical alarm switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HL32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2110-6HL32-0CL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W
3VA2110-6HL32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HL32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HL32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-6HL32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HL32-0CL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The 100 A continuous rating holds flat to 70 °C. The adjustable trip range (150–1200 A) means the same breaker frame can be set to protect a 200 A feeder or a 1000 A bus, but the continuous current rating of the breaker itself is 100 A — the trip unit setting must be coordinated with the load current and conductor ampacity, not just the frame's maximum. Enough for PLC feedback without adding external relay blocks.

Depth of 86 mm leaves clearance for rear-mounted busbars or cable ducts.

Frequently asked questions

What is the depth of 3VA2110-6HL32-0CL0?

86 mm (3.39 in).

What is the width of 3VA2110-6HL32-0CL0?

105 mm (4.13 in).

Does 3VA2110-6HL32-0CL0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) as the auxiliary release.

MPN
3VA2110-6HL32-0CL0