Skip to main content
Siemens 3VA2110-6HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2110-6HL32-0DA0 MCCB, 100 A, 3-Pole, 242

MPN3VA2110-6HL32-0DA0

Siemens SENTRON 3VA2110-6HL32-0DA0, molded case circuit breaker, 3-pole, 100 A rated continuous current Iu, ETU320 electronic trip unit, 242 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2110-6HL32-0AA0
3VA2110-6HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96.25 A
Current at 60 °C92.5 A
Current at 65 °C88.75 A
Current at 70 °C85 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V5 kA
Power loss, max.12.5 W
3VA2110-6HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2110-6HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-6HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HL32-0DA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Above that, the current must be derated linearly: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. Maximum power loss is 12.5 W.

Trip unit and auxiliary releases

The ETU320 overcurrent release provides electronic protection with adjustable settings (not detailed here). The supplied basic switch is 3VA2110-6HL32-0AA0.

The mechanical endurance is 20,000 operations. It is a line-protection device (not a motor-protection or generator-protection variant).

Frequently asked questions

Where can I buy 3VA2110-6HL32-0DA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3VA2110-6HL32-0DA0's listed depth (86 mm) on this component line?

The depth is 86 mm, width 105 mm, height 181 mm.

MPN
3VA2110-6HL32-0DA0