Siemens SENTRON 3VA2110-6HL32-0DC0 MCCB, 100 A, 3-Pole

MPN3VA2110-6HL32-0DC0

Siemens SENTRON 3VA2110-6HL32-0DC0, molded case circuit breaker, 3-pole, 100 A continuous rating, adjustable thermal-magnetic trip 150–1200 A, breaking capacity 242 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HL32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-6HL32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W
3VA2110-6HL32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HL32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HL32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-6HL32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HL32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-6HL32-0DC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, with a continuous current rating of 100 A that holds across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel thermal budgeting. The adjustable thermal-magnetic trip unit covers 150 A minimum to 1200 A maximum, so this breaker can be set to protect a feeder or a large motor branch without swapping the frame. Breaking capacity is 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — the 690 V figure is the one to watch if you are on a 690 V distribution system; that is a low-fault application only.

Integration details

Maximum power loss is 12.5 W — a modest figure that does not drive significant heat buildup in a ventilated enclosure, but worth including in your thermal calculation if the panel is sealed.

The adjustable trip range of 150–1200 A means this single frame covers a wide range of load currents; you set the trip coil to match the protected conductor, not the breaker frame.

Frequently asked questions

What are the physical dimensions of 3VA2110-6HL32-0DC0?

Width is 105 mm, height is 181 mm, and depth is 86 mm. The 86 mm depth is the critical clearance dimension for shallow enclosures.