Skip to main content
Siemens 3VA2110-6HL32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HL32-0JC0 SENTRON MCCB, 100 A, 3-Pole, 242

MPN3VA2110-6HL32-0JC0

Siemens SENTRON molded case circuit breaker, 3VA2110-6HL32-0JC0, 100 A continuous, 3-pole, 242 kA interrupting at 240 V, line protection design with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-6HL32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2110-6HL32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-6HL32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-6HL32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-6HL32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-6HL32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-6HL32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2110-6HL32-0JC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C, designed for line protection in distribution panels and industrial switchboards. It carries a 242 kA interrupting capacity at 240 V, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — the high short-circuit rating at low voltage makes it suitable for high-fault service-entrance or main-breaker positions where available fault current is substantial. The breaker ships with a built-in shunt trip (STL) and two HQ auxiliary switches, so it arrives ready for remote tripping and status feedback without additional accessory wiring.

Dimensions and panel fit

The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a standard MCCB footprint that fits most 3-pole panelboard and switchboard mounting patterns without modification. It dissipates a maximum of 10 W at rated load, so thermal management inside a sealed enclosure is straightforward — no forced cooling required for most installations.

Environmental and operating range

Rated for continuous operation from -25 °C to 70 °C ambient, and can be stored from -40 °C to 80 °C. The 100 A rating holds flat across the entire 40 °C to 70 °C operating range — no derating needed up to 70 °C.

Frequently asked questions

What is the depth of 3VA2110-6HL32-0JC0?

The depth is 86 mm (3.39 in).

MPN
3VA2110-6HL32-0JC0