Skip to main content
Siemens 3VA2110-6HN32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2110-6HN32-0DA0 MCCB, 100 A, 3-Pole

MPN3VA2110-6HN32-0DA0

Siemens SENTRON, molded case circuit breaker, 3VA2110-6HN32-0DA0, 3-pole, 100 A continuous, 242 kA breaking at 240 V, line protection with undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-6HN32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HN320AA0

Ratings

3VA2110-6HN32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W

Protection & Trip Unit

3VA2110-6HN32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-6HN32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-6HN32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2110-6HN32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-6HN32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries and where it fits

The 3VA2110-6HN32-0DA0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up near the kiln or the drive cabinet. Three-pole design, line-protection function, and an integrated undervoltage release (UVR) that trips the breaker when supply voltage drops below the dropout threshold — standard for safety circuits that need to kill power on loss of control voltage. Breaking capacity hits 242 kA at 240 V and 187 kA at 415 V, so it handles high-fault-current scenarios typical of large transformer secondaries or busway feeds without cascading upstream.

Sizing and coordination for the real panel

Rated insulation voltage is 800 V. The 100 A continuous rating is flat from 40 °C to 70 °C. Maximum power loss is 12.5 W, so ventilation requirements in the panel are modest for this frame size. Dimensions are 181 mm high, 105 mm wide, 86 mm deep — fits standard SENTRON 3VA mounting footprints. The 86 mm depth is the same as many 3VA2 frame breakers, so a panel laid out for a 3VA1020 will accept this unit without re-drilling the mounting plate.

MPN
3VA2110-6HN32-0DA0