Skip to main content
Siemens 3VA2110-6HN36-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-6HN36-0AF0 SENTRON MCCB, 100 A, 3-Pole, 242

MPN3VA2110-6HN36-0AF0

Siemens SENTRON molded case circuit breaker, 3VA2110-6HN36-0AF0, 3-pole, 100 A rated continuous current, 242 kA breaking capacity at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-6HN36-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21106HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2110-6HN36-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-6HN36-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-6HN36-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-6HN36-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2110-6HN36-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-6HN36-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this 100 A MCCB delivers — and where the fat isn't

The Siemens 3VA2110-6HN36-0AF0 is a SENTRON molded case circuit breaker rated for 100 A continuous current across the full ambient range up to 70 °C — no derating curve to chase at 40, 50, or 60 °C, it holds 100 A flat. Three-pole line-protection design, 800 V insulation voltage, and a breaking capacity that starts at 242 kA at 240 V and drops to 3.7 kA at 690 V — the SCCR headroom you need for high-fault utility feeds or transformer secondaries. At 10 W max power loss, this MCCB runs cool enough to pack tightly on a DIN rail — no forced ventilation required in a standard IP54 enclosure.

Frequently asked questions

Where can I buy 3VA2110-6HN36-0AF0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

Will 3VA2110-6HN36-0AF0 drop into a panel specified around 3VA2116-5HL32-0AK0 without rewiring?

Both are 3-pole SENTRON MCCBs on the same mounting footprint and busbar pitch, so mechanical fit is the same. The difference is rating — the 3VA2116-5HL32-0AK0 is a higher-current frame. Verify your load current against the 100 A continuous rating before substituting.

What compliance documentation does this brand provide for 3VA2110-6HN36-0AF0?

As a Siemens SENTRON product, this MCCB carries the standard IEC/UL certifications for the class. Specific RoHS, REACH, and UL file numbers are available in the manufacturer's declaration package — request them with your RFQ.

MPN
3VA2110-6HN36-0AF0