Skip to main content
Siemens 3VA2110-7HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-7HL32-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3

MPN3VA2110-7HL32-0AA0
Active

Siemens SENTRON 3VA molded case circuit breaker, 3VA2110-7HL32-0AA0, 3-pole, 100 A, ETU320 electronic trip unit, line protection, 330 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-7HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-7HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB with ETU320 — 100 A continuous, flat derating curve

The Siemens SENTRON 3VA2110-7HL32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, with a flat thermal derating curve holding 100 A from 40 °C through 70 °C — no reduction needed across typical panel ambient temperatures. Its ETU320 electronic trip unit supports an adjustable overload trip range from 150 A to 1,200 A. Breaking capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — the steep drop above 500 V means the 690 V rating governs any 690 V bus application.

Integration into a panel — dimensions and mounting

At 105 mm wide × 181 mm high × 86 mm deep, this 3VA frame fits standard Siemens 3VA mounting accessories and busbar systems; verify the existing panel cutout or DIN-rail adapter if retrofitting into a different brand's enclosure.

Maximum power loss is 10 W.

MPN
3VA2110-7HL32-0AA0