The Siemens SENTRON 3VA2110-7HM42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across its full operating temperature range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel thermal budgeting. The 100 A full-scale value and 20 A initial trip threshold mean it is sized for a 100 A feeder or large motor branch, with the adjustable thermal-magnetic trip unit allowing coordination downstream. Breaking capacity is the headline: 330 kA at 240 VAC, 242 kA at 415 VAC, and 242 kA at 440 VAC, dropping to 187 kA at 500 VAC and 3.7 kA at 690 VAC. The ground-fault monitoring version uses summation current formation of L + N conductors, meaning it measures vector sum of phase and neutral currents to detect leakage. That is a fit for TN or TT systems where residual current detection is needed at the breaker level without a separate RCD. Dimensions are 86 mm depth, 140 mm width, 181 mm height. At 140 mm wide for a 4-pole, it fits standard Siemens SENTRON panel mounting footprints; the 86 mm depth leaves clearance for rear-connected busbars or cable lugs in a typical 200 mm deep enclosure. Maximum power loss of 10 W means minimal heat contribution inside a sealed panel — no forced ventilation required for this single breaker.

Siemens SENTRON 3VA2110-7HM42-0AA0 MCCB, 100 A, 4-Pole, 330
MPN3VA2110-7HM42-0AA0
Active
Siemens SENTRON 3VA2110-7HM42-0AA0, molded case circuit breaker, 4-pole, 100 A continuous rated, 330 kA at 240 VAC, line protection design.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Parameter | Value |
|---|---|
| Number of poles | 4 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 100 A |
| Current at 45 °C | 100 A |
| Current at 50 °C | 100 A |
| Current at 55 °C | 100 A |
| Current at 60 °C | 100 A |
| Current at 65 °C | 100 A |
| Current at 70 °C | 100 A |
| Switching capacity class | C |
| Breaking capacity at 240 V | 330 kA |
| Breaking capacity at 415 V | 242 kA |
| Breaking capacity at 440 V | 242 kA |
| Breaking capacity at 500 V | 187 kA |
| Breaking capacity at 690 V | 3.7 kA |
| Power loss, max. | 10 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU330 |
| Overcurrent protection function | LIG |
| Ground-fault monitoring | Summation current formation L + N conductor |
| Grounding protection function | Yes |
| Parameter | Value |
|---|---|
| Main circuit connection type | on both sides nut keeper kit |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 25 000 |
| Height | 181 mm |
| Width | 140 mm |
| Depth | 86 mm |
| Height (in) | 7.13 in |
| Width (in) | 5.51 in |
| Depth (in) | 3.39 in |
Product details
MPN
3VA2110-7HM42-0AA0