Siemens 3VA2110-7HN46-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA2110-7HN46-0AA0 SENTRON MCCB, 1200 A, 4-Pole, ETU350

MPN3VA2110-7HN46-0AA0
Active

Siemens SENTRON 3VA2110-7HN46-0AA0, molded case circuit breaker, 4-pole, 1200 A rated continuous current, ETU350 electronic trip unit, breaking capacity 330 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7HN46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-7HN46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7HN46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7HN46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7HN46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-7HN46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7HN46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

1200 A frame, ETU350 — selectivity without the guesswork

That 1200 A rating is the maximum continuous current the frame can carry — it's not derated for ambient temperature up to 70 °C, where it still holds 100 A continuous.

Breaking capacity that follows the voltage

This MCCB's interrupting rating drops as system voltage rises — 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. For most 400 V-class distribution, 242 kA gives generous headroom over typical utility transformer fault levels.

The case measures 140 mm wide, 181 mm high, and 86 mm deep — it's a standard 4-pole MCCB footprint for a 1200 A frame. Power dissipation maxes at 10 W, so panel heating is minimal.

Frequently asked questions

What is the breaking capacity of 3VA2110-7HN46-0AA0 at 415 V?

242 kA at 415 V AC. The same rating applies at 440 V. At 240 V it rises to 330 kA, and at 690 V it drops to 3.7 kA.

Where can I buy 3VA2110-7HN46-0AA0?

This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery window.

What does the ETU350 trip unit do?

The ETU350 is an electronic trip unit with adjustable long-time, short-time, instantaneous, and ground-fault protection. It allows fine coordination with downstream breakers in selective distribution schemes.