Skip to main content
Siemens 3VA2110-7KP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-7KP32-0AA0 SENTRON MCCB, 100 A, ETU850, 3-Po

MPN3VA2110-7KP32-0AA0
Active

Siemens SENTRON 3VA2110-7KP32-0AA0, molded case circuit breaker, 3-pole, 100 A continuous, ETU850 electronic trip unit, line protection design, IP40 front, 86 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7KP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2110-7KP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7KP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7KP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7KP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2110-7KP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7KP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Rated insulation voltage is 800 V, and the interrupting ratings climb to 330 kA at 240 V and 242 kA at 415/440 V, dropping to 187 kA at 500 V and 3.7 kA at 690 V — the SCCR headroom at typical low-voltage distribution levels (240–480 V) is substantial, making this a strong candidate for high-fault-capacity main or feeder positions.

The 3VA2110-7KP32-0AA0 measures 105 mm wide, 181 mm high, and 86 mm deep — a 3-pole MCCB footprint that drops into standard SENTRON mounting bases and busbar systems.

Environmental limits and handling

Frequently asked questions

What is the continuous current rating of this MCCB?

100 A continuous, and it holds that rating from 40 °C through 70 °C ambient without derating.

What trip unit does the 3VA2110-7KP32-0AA0 use?

The ETU850 electronic trip unit, which supports communication and additional measurement functions.

What are the interrupting ratings at common voltages?

330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V.

Where can I buy the 3VA2110-7KP32-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2110-7KP32-0AA0