MPN3VA2110-7MN32-0HL0

Siemens SENTRON series, molded case circuit breaker, 3VA2110-7MN32-0HL0, 3-pole, 100 A, motor protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7MN32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21107MN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2110-7MN32-0HL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7MN32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7MN32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7MN32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-7MN32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7MN32-0HL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2110-7MN32-0HL0 is a 3-pole molded case circuit breaker rated for 100 A continuously across the full ambient range from 40 °C to 70 °C — no derating needed in a warm panel. The interrupting capacity hits 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 3.7 kA at 690 V. That 330 kA figure means it can handle a direct fault on a high-capacity transformer secondary without upstream coordination problems.

The 105 mm width takes three pole widths at 35 mm each, so it occupies the same slot as any other 3-pole 3VA2 MCCB. Power dissipation maxes at 10 W, negligible for thermal budgeting inside a closed enclosure.

Motor protection specifics

The motor protection design means the trip curve is shaped for motor inrush — it tolerates the 6-8x FLA starting current for the adjustable time band (minimum 4 s, maximum 17 s,) before tripping on overload. Phase failure detection catches a lost phase on the line side and trips before single-phasing damages the motor. The shunt trip release (STL) allows a remote emergency-stop or PLC-driven trip without undervoltage release. No ground-fault monitoring module is integrated; add an external module if GF protection is required.

Frequently asked questions

What are the key ratings for 3VA2110-7MN32-0HL0?

It's a 3-pole, 100 A MCCB rated continuously from 40 °C to 70 °C (-). Interrupting capacity is 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 3.7 kA at 690 V (-). Motor protection design with phase failure detection.

Will 3VA2110-7MN32-0HL0 drop into a panel specified for 3VA2110-7HK42-0AA0?

Both are 3-pole SENTRON 3VA2 frame MCCBs with the same 105 mm width and 181 mm height, so the mechanical footprint is identical. The key difference is the rating and accessories: this unit is 100 A with motor protection, phase failure detection, and a shunt trip release. The 7HK42 variant may have different trip characteristics or auxiliary configuration. Check the trip curve and accessory count against your BOM before swapping.

How do I get current pricing and availability for 3VA2110-7MN32-0HL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.