Specifications

3VA2110-7MN36-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21107MN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2110-7MN36-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.12.5 W
3VA2110-7MN36-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7MN36-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7MN36-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-7MN36-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7MN36-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Product identity and role

Breaking capacity and fault clearance

This MCCB delivers a rated ultimate short-circuit breaking capacity (Icu) of 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The high 330 kA figure at 240 V makes this unit suitable for installation close to large step-down transformers or busway taps where fault current can exceed 200 kA.

Motor protection and auxiliary complement

Designed for motor protection, the 3VA2110-7MN36-0DL0 includes phase failure detection as a built-in function — essential for preventing single-phasing damage on three-phase motor loads.

Physical integration and environmental limits

Maximum power loss is 12.5 W, which should be factored into enclosure thermal calculations for sealed panels.

Frequently asked questions

Where can I buy 3VA2110-7MN36-0DL0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the breaking capacity of 3VA2110-7MN36-0DL0 at 415 V?

The rated ultimate short-circuit breaking capacity at 415 V is 242 kA. At 240 V it is 330 kA, at 500 V it is 187 kA, and at 690 V it is 3.7 kA.

Does 3VA2110-7MN36-0DL0 include phase failure protection?

Yes, phase failure detection is a built-in function on this motor protection MCCB, along with an undervoltage release.