Skip to main content
Siemens 3VA2110-7MN36-0JL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-7MN36-0JL0 SENTRON MCCB, 100 A, 3-Pole, Moto

MPN3VA2110-7MN36-0JL0

Siemens SENTRON 3VA2110-7MN36-0JL0, molded case circuit breaker, 3-pole, 100 A, motor protection design, 330 kA at 240 V breaking capacity, 86 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7MN36-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21107MN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2110-7MN36-0JL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7MN36-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7MN36-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7MN36-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-7MN36-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7MN36-0JL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2110-7MN36-0JL0 — 100 A MCCB for Motor Protection

It's a 3-pole unit with phase failure detection built in, so it catches a lost phase before the motor cooks.

Breaking Capacity — What the Voltage Steps Mean

This MCCB carries a massive 330 kA breaking capacity at 240 V, dropping to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and 3.7 kA at 690 V.

Panel Fit & Integration

The 3VA2110-7MN36-0JL0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that drops into a SENTRON panelboard or a DIN-rail adapter kit. Power loss is 10 W maximum, so thermal rise in a sealed enclosure is manageable — no forced ventilation required for a single unit.

Frequently asked questions

What is the breaking capacity of 3VA2110-7MN36-0JL0 at 415 V?

At 415 V, the breaking capacity is 242 kA. At 240 V it's 330 kA, at 500 V it's 187 kA, and at 690 V it's 3.7 kA.

Does the 3VA2110-7MN36-0JL0 include phase failure detection?

Yes, phase failure detection is built into this motor protection MCCB, so it will trip on a lost phase.

What auxiliary switches come with 3VA2110-7MN36-0JL0?

It ships with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch HQ, plus a shunt trip release (STL) for remote tripping.

Where can I buy 3VA2110-7MN36-0JL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2110-7MN36-0JL0