Siemens 3VA2110-7MQ36-0AA0 SENTRON MCCB, 100 A, 3-pole, moto

MPN3VA2110-7MQ36-0AA0
Active

Siemens SENTRON 3VA2110-7MQ36-0AA0, molded case circuit breaker, 3-pole, 100 A, motor protection design, communication function, 330 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-7MQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2110-7MQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-7MQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860M
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2110-7MQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-7MQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2110-7MQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-7MQ36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it protects

The Siemens SENTRON 3VA2110-7MQ36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 100 A continuous across the full ambient range from 40 °C to 70 °C — no derating needed in a warm enclosure. It is explicitly designed for motor protection, with phase failure detection and ground-fault monitoring via summation current formation on the L-conductor. Communication function is built in, so it can report status and trip events to a PLC or SCADA without an add-on module.

Breaking capacity — the real fault-handling envelope

This MCCB delivers 330 kA interrupting capacity at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The steep drop above 500 V means the 690 V rating is limited to 3.7 kA — adequate for secondary-side protection on a 690 V distribution but not for high-fault service-entrance duty at that voltage. The 330 kA at 240 V covers most North American panelboard and motor control center applications with generous headroom.

Panel fit and integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. Maximum power loss is 10 W, so ventilation in a sealed enclosure is not critical. The undervoltage release is absent on this variant; if undervoltage protection is needed, that function must be provided externally or by a different order code.

Protection and measurement features

Beyond motor protection and phase failure detection, this breaker includes an other measurement function — energy or power metering via the communication interface. The ground-fault monitoring uses summation current formation on the L-conductor.

Environmental limits

Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage minimum is the handling limit — the breaker can sit in a cold warehouse without damage, but must be above -25 °C to be energized.

Frequently asked questions

What compliance documentation does Siemens provide for this breaker?

Siemens SENTRON MCCBs carry UL, CSA, and IEC certifications as standard. RoHS and REACH declarations are available through Siemens Industry Online Support. Specific documentation for this order code can be requested at quote time.