Skip to main content
Siemens 3VA2110-7MS32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-7MS32-0AD0 SENTRON MCCB, 100 A, 3-Pole, 330

MPN3VA2110-7MS32-0AD0

Siemens SENTRON 3VA2110-7MS32-0AD0, molded case circuit breaker, 3-pole, 100 A continuous, 330 kA interrupting at 240 V, starter protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7MS32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21107MS320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2110-7MS32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7MS32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7MS32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7MS32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-7MS32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7MS32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — the steep drop above 500 V means you verify the available fault current at the point of installation before committing the BOM line. The design is explicitly for starter protection, so it is sized to sit ahead of a motor starter combination — not a general distribution feeder — and carries three auxiliary switches HQ as standard.

The 3VA2110-7MS32-0AD0 measures 86 mm deep, 105 mm wide, and 181 mm tall — a 3-pole MCCB footprint that fits standard SENTRON panel cutouts and busbar spacing. Maximum power loss is 10 W; plan for that thermal load inside the enclosure, especially when multiple breakers are ganged.

Frequently asked questions

What are the physical dimensions of 3VA2110-7MS32-0AD0?

86 mm deep, 105 mm wide, 181 mm tall.

MPN
3VA2110-7MS32-0AD0