Skip to main content
Siemens 3VA2110-7MS32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-7MS32-0HH0 SENTRON MCCB, 100 A, 1500 A max t

MPN3VA2110-7MS32-0HH0

Siemens SENTRON 3VA2110-7MS32-0HH0, 3-pole molded case circuit breaker, 100 A rated, adjustable thermal-magnetic trip 300-1500 A, breaking capacity 330 kA at 240 V, 242 kA at 415 V, 187 kA at 500 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7MS32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21107MS320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2110-7MS32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W
3VA2110-7MS32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2110-7MS32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7MS32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2110-7MS32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7MS32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Panel-builder commissioning note

The Siemens SENTRON 3VA2110-7MS32-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous at 40 °C through 70 °C with no derating — that's unusual thermal stability for a 100 A frame. Adjustable thermal-magnetic trip covers 300 A to 1 500 A, so you can dial it to protect motor or feeder circuits without swapping the breaker body. Breaking capacity hits 330 kA at 240 V, 242 kA at 415 V, and 187 kA at 500 V, which puts it in the high-interrupting category for industrial distribution panels. Power loss maxes at 10 W, manageable for dense DIN-rail layouts in a 105 mm wide x 181 mm tall x 86 mm deep footprint.

The 105 mm width x 181 mm height x 86 mm depth fits standard MCCB panel cutouts.

Frequently asked questions

Where can I buy 3VA2110-7MS32-0HH0 and how do I get a price?

Sourced through independent distribution channels. Submit an RFQ for current pricing and availability confirmation at quote time.

What is the breaking capacity of 3VA2110-7MS32-0HH0 at different voltages?

330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The steep drop at 690 V means this breaker is designed for 240-500 V industrial distribution, not 690 V motor circuits.

MPN
3VA2110-7MS32-0HH0